There are no more items in your cart
search
Tegui 374001. Connection hose between columns for the connection between SERIES 7 plates of the Conventional…
Tegui 374001. Connection hose between columns for the connection between SERIES 7 plates of the Conventional system placed on their sides. One patch cord is required for each additional column. 70cm. of length.
€5.49
Tax included
Reference
tegui-374001
Brand
Tegui
Tegui 374001. Connection hose between columns for the connection between SERIES 7 plates of the Conventional…
€5.49
Connection hose between columns for the connection between SERIES 7 plates of the Conventional system placed on their sides.
One patch cord is required for each additional column.
70cm.
of length.
| Features | Value |
|---|---|
| Halogen free according to EN IEC 60754-2 | - |
| Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | None |
| Cable height approx. | 6 mm |
| Reaction-to-fire according to EN 13501-6: Smoke production | None |
| Reaction-to-fire according to EN 13501-6: Class | None |
| Number of pilot/reduced conductors | - |
| Cable width approx. | 5 mm |
| Nominal cross section pilot/reduced conductors | - mm² |
| Weight | - kg |
| Low temperature resistant according to EN 60811-504+505+506 | No |
| Oil resistant according to EN IEC 60811-404 | No |
| Conductor surface | Bare |
| Material armouring | - |
| Number of stranding elements | - |
| Torsion resistant | No |
| Reaction-to-fire according to EN 13501-6: Acidity | None |
| Min. permitted bending radius, stationary application/permanent installation | - mm |
| Min. permitted bending radius, moving application/free movement | - mm |
| Min. permitted bending radius, moving application with forced guidance | - mm |
| Shape of conductor | Round |
| Specification material outer sheath | - |
| Specification core insulation | - |
| Colour outer sheath | Grey |
| Number of strands per conductor | - |
| Conductor resistance at 20 °C | - Ohm/km |
| Halogen free according to EN IEC 60754-3 | - |
| Strand diameter | - mm |
| Low smoke according to EN IEC 61034-2 | No |
| Nominal voltage U | 12 kV |
| Stranding element | No |
| Nominal voltage U0 | 12 kV |
| Number of cores | 3 |
| Screen | - |
| Core identification | Other |
| Suspension element | None |
| Material core insulation | - |
| Nominal cross section conductor | 0.16 mm² |
| Halogen free according to EN IEC 60754-1 | - |
| Flame retardant according to IEC 60332-3-24 (Cat C) | - |
| Flame retardant according to IEC 60332-3-25 (Cat D) | - |
| Conductor material | Copper |
| Screen over stranding | None |
| Screen over stranding element | None |
| Outer diameter approx. | 2 mm |
| Drain wire | - |
| Flame retardant according to IEC 60332-3-22 (Cat A) | - |
| Material outer sheath | - |
| Flame retardant according to IEC 60332-3-23 (Cat B) | - |
| Flame retardant according to IEC 60332-1-2 | - |
| Max. conductor temperature | - °C |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | - |
| Protective barrier | - |
| AWG size | 26 |
| Armouring/reinforcement | - |
| Permitted cable outer temperature after assembling without vibration | - °C |
| Permitted cable outer temperature during assembling/handling | - °C |
| With protective conductor | No |
| Core identification according to HD 308 S2 | - |
| Max. tensile strength during installation | - kN |
| Cable geometry | Flat |
| Conductor category | Class 6 = very flexible |
| Nominal cross section pilot/reduced conductors (AWG) | - |
| Nominal cross section conductor (AWG) | - kcmil |