There are no more items in your cart
search
Dmtech DMT-FP9000-24-PT - Conventional central 24 areas with LCD screen, 2 Siren…
Conventional central 24 areas with LCD screen - 2 Siren output - 2 alarm and fault outputs and 10 configurable relay outputs - Repeater output - Up to 30 detectors per zone - End-of-line resistance auto detection
€730.00
Tax included
Reference
DMT-FP9000-24-PT
Brand
Dmtech
Dmtech DMT-FP9000-24-PT - Conventional central 24 areas with LCD screen, 2 Siren…
€730.00
You might also like
- DMTECH
- Conventional fire alarm panel of 24 zones
- Certificate EN54-2 and EN54-4
- 2 independent siren outputs
- 2 auxiliary alarm and fault outputs
- 10 configurable relay outputs
- Individual output for repeaters
- Capacity for 2 12V batteries
- 4 access levels ((3 user and 1 manufacturer)
- LCD display with menu for advanced programming
Features
- Conventional central 24 areas with LCD screen
- 2 Siren output
- 2 alarm and fault outputs and 10 configurable relay outputs
- Repeater output
- Up to 30 detectors per zone
- End-of-line resistance auto detection
Specs
| Primary power supply | Switching source 187-252V AC 50-60 Hz 65W max. |
| Backup power supply | 2 batteries 12VDC (up to 18 Ah). Ensures minimum 72 hours duration. |
| Available languages | Spanish, English, Portuguese, Italian, French, and German. |
| Number of zones | 24 zones, up to 30 detectors by area. |
| Siren outputs | 2 siren outputs 24VDC. Independent and monitored open collector outputs |
| Relay outputs | 12 Relay outputs: [VAR%] Alarm output, 1 Fault output and 1 configurable relay outputs. All support 30VDC 3A max. |
| End of line resistance | Areas fully monitored by end-of-line resistance (4.7K) |
| Auxiliary Output Voltage | 24VDC. Protected by resettable electronic fuse 1.85A |
| Protection Index | IP30 |
| Temperature | -5ºC~+45ºC |
| Material and colour | ABS, colour: White |
| Dimensions | 370 x 410 x 80 mm |
| Weight | 2.5Kg |
| Recommended cable | Fire cable with a minimum section of 1.0mm (18AWG). |
Package content
- Panels
- Battery cables
- Fusible
- End of line resistors
Data sheet
- Weight
- 2.5Kg
- LED indicators
- 22 red (1 x fire, 1 x more alarms, 20 x programmable zone), 1 green (power), 13 amber and 12 bicolor (fault and system)
- Dimensions
- 150mm (H) x 80mm (W) x 49mm (D)
370 x 410 x 80 mm - Material
- Methacrylate
- Mounting
- Surface
- Temperature
- -5ºC~+45ºC
- Primary power supply
- Switching source 187-252V AC 50-60 Hz 65W max.
- Backup power supply
- 2 batteries 12VDC (up to 18 Ah). Ensures minimum 72 hours duration.
- Number of zones
- 24 zones, up to 30 detectors by area.
2000 (200 per panel) - Siren outputs
- 2 siren outputs 24VDC. Independent and monitored open collector outputs
- Relay outputs
- 12 Relay outputs: [VAR%] Alarm output, 1 Fault output and 1 configurable relay outputs. All support 30VDC 3A max.
- End of line resistance
- Areas fully monitored by end-of-line resistance (4.7K)
- Auxiliary Output Voltage
- 24VDC. Protected by resettable electronic fuse 1.85A
- Protection Index
- IP30
- Material and colour
- ABS, colour: White
- Recommended cable
- Fire cable with a minimum section of 1.0mm (18AWG).
- Display
- 240 x 64 white backlit LCD screen.
- Protocols
- Argus Vega (preinstalled), Apollo (XP95 / Discovery), Hochiki ESP and Nittan Evolution
- Available languages
- Spanish, English, Portuguese, Italian, French, and German.
- Core technology
- Dual flash-based processors with real-time clock, diagnostics, programmable languages and character sets
- Controls
- Alphanumeric keypad that allows navigation, Reset, Mute buzzer, Mute sirens, Resonate, Evacuate and x4 programmable push-buttons
- Number of loops
- 1
- Loop devices
- 240 in Argus Vega protocol (pre-installed), in the others it depends on the protocol
- Loop
- 500mA
- Siren outputs on plate
- 2 x 1 Programmable Amp
- Relay outputs on plate
- 2 x 1 Amp 30v AC/DC programable(10mA, 5v min) - expandable to 4
- Auxiliary output
- 24V 500mA
- Programmable inputs
- 1 x programmable supervised input in plate
- Programmable key switch inputs
- 1 x Voltage-free input (standard enc.), 8 x inputs (M, L, D enc.)
- Total output current available
- 3A maximum available for loop current + siren outputs + auxiliary power
- Main power supply
- 200 - 240v 47-63 Hz AC (+10%, -15% tolerance) 1.0A Max
- Charger current
- 1A with temperature compensation
- Serial port interface
- 1 x in plate, connection for PC RS232, modem, IP, or portable printer
- USB interface
- 1 x USB Type B for PC connection
- Program
- Keypad and LCD (built-in) or PC with Windows software
- Event Buffer
- 5000 for events and diagnosis + 500 fires
- Networks
- Optional network card (ADV-MXP-503 - standard, or ADV-MXP-509 - fault tolerant)
- Printer (optional)
- In plate (only in the M, L, D boxes)
- Box / Color
- Steel IP30 / RAL7035
- Metalwork Options
- Flush Mount Bezel, Battery Box, Special Utility Boxes, Termination Boxes and Rack Mount Profile
- Dimensions (H x W x D mm)
- Standard: 345 x 345 x 85 Medium: 345 x 430 x 120 Large: 475 x 450 x 120 Big Deep: 475 x 450 x 190
- Battery capacity (Min - Max)
- Standard: 24V 4Ah - 24V 7Ah Medium: 24V 4Ah - 24V 12Ah Large: 24V 4Ah - 24V 18Ah Big Deep: 24V 4Ah - 24V 45Ah
- Cable entry (20mm knockouts)
- Standard: 13 x above, 8 x rear Medium: 17 x above, 11 x rear Large: 19 x above, 11 x rear Big Deep: 30 x above, 11 x rear and 3 x below