No hay más artículos en su carrito
search
Dmtech DMT-FP9000L-4-IT - 4 Zone Conventional Fire Alarm Panel, 2 Siren output,…
4 Zone Conventional Fire Alarm Panel - 2 Siren output - 2 alarm and fault outputs and 2 configurable relay outputs - Repeater output - Up to 30 detectors per zone - End-of-line resistance auto detection
122,00 €
Impuestos incluidos
Referencia
DMT-FP9000L-4-IT
Marca
Dmtech
Dmtech DMT-FP9000L-4-IT - 4 Zone Conventional Fire Alarm Panel, 2 Siren output,…
122,00 €
También podría interesarle
- DMTECH
- Conventional fire alarm panel of 4 zones
- Certificate EN54-2 and EN54-4
- 2 independent siren outputs
- 2 auxiliary alarm and fault outputs
- 2 configurable relay outputs
- Individual output for repeaters
- Capacity for 2 12V batteries
- 4 access levels ((3 user and 1 manufacturer)
Caracteristicas
- 4 Zone Conventional Fire Alarm Panel
- 2 Siren output
- 2 alarm and fault outputs and 2 configurable relay outputs
- Repeater output
- Up to 30 detectors per zone
- End-of-line resistance auto detection
Especificaciones
| Primary power supply | Switching source 187-252V AC 50-60 Hz 65W max. |
| Backup power supply | 2 batteries 12VDC (up to 5 Ah). Ensures minimum 90 hours duration. |
| Number of zones | 4 zones, up to 30 detectors by area. |
| Siren outputs | 2 siren outputs 24VDC. Independent and monitored open collector outputs |
| Relay outputs | 4 Relay outputs: [VAR%] Alarm output, 1 Fault output and 1 configurable relay outputs. All support 30VDC 3A max. |
| End of line resistance | Areas fully monitored by end-of-line resistance (4.7K) |
| Auxiliary Output Voltage | 24VDC. Protected by resettable electronic fuse 1.85A |
| Protection Index | IP30 |
| Temperature | -5ºC~+45ºC |
| Material and colour | ABS, colour: White |
| Dimensions | 310 x 240 x 80 mm |
| Weight | 1,3Kg |
| Recommended cable | Fire cable with a minimum section of 1.0mm (18AWG). |
Contenido del paquete
- Panels
- Battery cables
- Fusible
- End of line resistors
Ficha técnica
- Peso
- 1,3Kg
- Dimensiones
- 310 x 240 x 80 mm
- Temperatura
- -5ºC~+45ºC
- Alimentación Primaria
- Fuente conmutada 187-252V AC 50-60 Hz 65W max.
- Alimentación Secundaria
- 2 baterías 12VDC (hasta 5 Ah). Asegura mínimo 90 horas de duración.
- Número de Zonas
- 4 zonas, hasta 30 detectores por zona.
- Salidas de sirena
- 2 Salidas de sirena 24VDC. Salidas de colector abierto independiente y monitoreadas
- Salidas de relé
- 4 Salidas de Relé: 1 Salida de Alarma, 1 Salida de fallo y 2 salidas de relé configurables. Todas admiten 30VDC 3A máx.
- Resistencia de fin de linea
- Zonas totalmente monitoreadas por resistencia de final de línea (4.7K)
- Tensión de Salida Auxiliar
- 24VDC. Protegido por fusible electrónico rearmable 1.85A
- Índice de Protección
- IP30
- Material y Color
- ABS, Color: Blanco
- Cable recomendable
- Cable de fuego con una sección mínima de 1.0mm (18AWG).