Il n'y a plus d'articles dans votre panier
search
Dmtech DMT-FP9000L-2-PT - 2 Zone Conventional Fire Alarm Panel, 2 Siren output,…
2 Zone Conventional Fire Alarm Panel - 2 Siren output - 2 alarm and fault outputs and 2 configurable relay outputs - Repeater output - Up to 30 detectors per zone - End-of-line resistance auto detection
108,00 €
TTC
Référence
DMT-FP9000L-2-PT
Marque
Dmtech
Dmtech DMT-FP9000L-2-PT - 2 Zone Conventional Fire Alarm Panel, 2 Siren output,…
108,00 €
Vous aimerez aussi
- DMTECH
- Conventional fire alarm panel of 2 zones
- Certificate EN54-2 and EN54-4
- 2 independent siren outputs
- 2 auxiliary alarm and fault outputs
- 2 configurable relay outputs
- Individual output for repeaters
- Capacity for 2 12V batteries
- 4 access levels ((3 user and 1 manufacturer)
Caractéristiques
- 2 Zone Conventional Fire Alarm Panel
- 2 Siren output
- 2 alarm and fault outputs and 2 configurable relay outputs
- Repeater output
- Up to 30 detectors per zone
- End-of-line resistance auto detection
Spécifications
| Primary power supply | Switching source 187-252V AC 50-60 Hz 65W max. |
| Backup power supply | 2 batteries 12VDC (up to 5 Ah). Ensures minimum 120 hours duration. |
| Number of zones | 4 zones, up to 30 detectors by area. |
| Siren outputs | 2 siren outputs 24VDC. Independent and monitored open collector outputs |
| Relay outputs | 4 Relay outputs: [VAR%] Alarm output, 1 Fault output and 1 configurable relay outputs. All support 30VDC 3A max. |
| End of line resistance | Areas fully monitored by end-of-line resistance (4.7K) |
| Auxiliary Output Voltage | 24VDC. Protected by resettable electronic fuse 1.85A |
| Protection Index | IP30 |
| Temperature | -5ºC~+45ºC |
| Material and colour | ABS, colour: White |
| Dimensions | 310 x 240 x 80 mm |
| Weight | 1,3Kg |
| Recommended cable | Fire cable with a minimum section of 1.0mm (18AWG). |
Contenu de l'emballage
- Panels
- Battery cables
- Fusible
- End of line resistors
Fiche technique
- Poids
- 1,3Kg
- Dimensions
- 310 x 240 x 80 mm
- Température
- -5ºC~+45ºC
- Alimentation primaire
- Fuente conmutada 187-252V AC 50-60 Hz 65W max.
- Alimentation Secondaire
- 2 batteries 12VDC (jusqu\'à 5 Ah). Garantit une durée minimale de 120 heures.
- Nombre de Zones
- 4 zones, jusqu\'à 30 detecteurs par zone.
- Sorties sirène
- 2 Sorties sirène 24VDC. Sorties de collecteur ouvert indépendant et contrôlées
- Sorties relais
- 4 Salidas de Relé: 1 Salida de Alarma, 1 Salida de fallo y 2 salidas de relé configurables. Todas admiten 30VDC 3A máx.
- Résistance de fin de ligne
- Zones entièrement surveillées par résistance de fin de ligne (4.7K)
- Tension de Sortie Auxiliaire
- 24VDC. Protegido por fusible electrónico rearmable 1.85A
- Indice de Protection
- IP30
- Matériel et couleur
- ABS, Couleur: Blanc
- Câble recommandé
- Cable de fuego con una sección mínima de 1.0mm (18AWG).